TOOLING COMPONENTS

FULL CONTACT(tm) CLAMP INSTALLATION INSTRUCTIONS
BASE PLATE
1. Position holes, drill and tap per chart "C" measurement.
2. Drill and ream hole for Press Fit Cone per chart "A" and "B" measurement (Figure-1).
3. Press cone into reamed hole using standard hex bolt and nut. Hold bolt stationary and turn hex nut to press cone into position.
NOTES:
It is recommended that a 8-32 x 1/2" P-Truss retainer screw be used with a 3/4" and larger Full-Contact Clamp (Refer to figure-1 and chart "G").
An adhesive or an Epoxy may be used in place of the retaining screw.

 

1/2"

3/4"

1"

(A) REAMED HOLE DIAMETER

.490

.740

.950

(B) REAMED HOLE DEPTH

.150

.160

.160

(C) TAPPED HOLE

3/8-16

1/2-13

3/4-10

(D) RETAINER CENTER LINE

-

.525

.630

(E) RETAINER SCREW COUNTER BORE

-

.110

.110

(F) RETAINER SCREW HEAD DIAMETER

-

.380

.380

(G) RETAINER SCREW

-

8-32X1/2 P-TRUSS

8-32X1/2 P-TRUSS

(H) FIXTURE PLATE HOLE DIAMETER

.495 - .515

.745 - .765

.995 - 1.015

OPTIONAL HEADLINER BUSHING

HL 48-12

HL 64-16

HL 88-16

MAX. LOAD

4200 LBS.

7500 LBS.

1100 LBS.

                              

FIXTURE PLATE
1. Position hole to match Base Plate Hole Locations. Drill and ream to dimensions as
required in chart "H" measurement.
2. If optional liner bushing is used, drill and ream per bushing manufacturer recommend


                           